diff options
author | Matt A. Tobin <mattatobin@localhost.localdomain> | 2018-02-02 04:16:08 -0500 |
---|---|---|
committer | Matt A. Tobin <mattatobin@localhost.localdomain> | 2018-02-02 04:16:08 -0500 |
commit | 5f8de423f190bbb79a62f804151bc24824fa32d8 (patch) | |
tree | 10027f336435511475e392454359edea8e25895d /testing/mozharness/mozprocess/winprocess.py | |
parent | 49ee0794b5d912db1f95dce6eb52d781dc210db5 (diff) | |
download | UXP-5f8de423f190bbb79a62f804151bc24824fa32d8.tar UXP-5f8de423f190bbb79a62f804151bc24824fa32d8.tar.gz UXP-5f8de423f190bbb79a62f804151bc24824fa32d8.tar.lz UXP-5f8de423f190bbb79a62f804151bc24824fa32d8.tar.xz UXP-5f8de423f190bbb79a62f804151bc24824fa32d8.zip |
Add m-esr52 at 52.6.0
Diffstat (limited to 'testing/mozharness/mozprocess/winprocess.py')
-rw-r--r-- | testing/mozharness/mozprocess/winprocess.py | 457 |
1 files changed, 457 insertions, 0 deletions
diff --git a/testing/mozharness/mozprocess/winprocess.py b/testing/mozharness/mozprocess/winprocess.py new file mode 100644 index 000000000..6f3afc8de --- /dev/null +++ b/testing/mozharness/mozprocess/winprocess.py @@ -0,0 +1,457 @@ +# A module to expose various thread/process/job related structures and +# methods from kernel32 +# +# The MIT License +# +# Copyright (c) 2003-2004 by Peter Astrand <astrand@lysator.liu.se> +# +# Additions and modifications written by Benjamin Smedberg +# <benjamin@smedbergs.us> are Copyright (c) 2006 by the Mozilla Foundation +# <http://www.mozilla.org/> +# +# More Modifications +# Copyright (c) 2006-2007 by Mike Taylor <bear@code-bear.com> +# Copyright (c) 2007-2008 by Mikeal Rogers <mikeal@mozilla.com> +# +# By obtaining, using, and/or copying this software and/or its +# associated documentation, you agree that you have read, understood, +# and will comply with the following terms and conditions: +# +# Permission to use, copy, modify, and distribute this software and +# its associated documentation for any purpose and without fee is +# hereby granted, provided that the above copyright notice appears in +# all copies, and that both that copyright notice and this permission +# notice appear in supporting documentation, and that the name of the +# author not be used in advertising or publicity pertaining to +# distribution of the software without specific, written prior +# permission. +# +# THE AUTHOR DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS SOFTWARE, +# INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. +# IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY SPECIAL, INDIRECT OR +# CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS +# OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, +# NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION +# WITH THE USE OR PERFORMANCE OF THIS SOFTWARE. + +from ctypes import c_void_p, POINTER, sizeof, Structure, Union, windll, WinError, WINFUNCTYPE, c_ulong +from ctypes.wintypes import BOOL, BYTE, DWORD, HANDLE, LPCWSTR, LPWSTR, UINT, WORD, ULONG +from qijo import QueryInformationJobObject + +LPVOID = c_void_p +LPBYTE = POINTER(BYTE) +LPDWORD = POINTER(DWORD) +LPBOOL = POINTER(BOOL) +LPULONG = POINTER(c_ulong) + +def ErrCheckBool(result, func, args): + """errcheck function for Windows functions that return a BOOL True + on success""" + if not result: + raise WinError() + return args + + +# AutoHANDLE + +class AutoHANDLE(HANDLE): + """Subclass of HANDLE which will call CloseHandle() on deletion.""" + + CloseHandleProto = WINFUNCTYPE(BOOL, HANDLE) + CloseHandle = CloseHandleProto(("CloseHandle", windll.kernel32)) + CloseHandle.errcheck = ErrCheckBool + + def Close(self): + if self.value and self.value != HANDLE(-1).value: + self.CloseHandle(self) + self.value = 0 + + def __del__(self): + self.Close() + + def __int__(self): + return self.value + +def ErrCheckHandle(result, func, args): + """errcheck function for Windows functions that return a HANDLE.""" + if not result: + raise WinError() + return AutoHANDLE(result) + +# PROCESS_INFORMATION structure + +class PROCESS_INFORMATION(Structure): + _fields_ = [("hProcess", HANDLE), + ("hThread", HANDLE), + ("dwProcessID", DWORD), + ("dwThreadID", DWORD)] + + def __init__(self): + Structure.__init__(self) + + self.cb = sizeof(self) + +LPPROCESS_INFORMATION = POINTER(PROCESS_INFORMATION) + +# STARTUPINFO structure + +class STARTUPINFO(Structure): + _fields_ = [("cb", DWORD), + ("lpReserved", LPWSTR), + ("lpDesktop", LPWSTR), + ("lpTitle", LPWSTR), + ("dwX", DWORD), + ("dwY", DWORD), + ("dwXSize", DWORD), + ("dwYSize", DWORD), + ("dwXCountChars", DWORD), + ("dwYCountChars", DWORD), + ("dwFillAttribute", DWORD), + ("dwFlags", DWORD), + ("wShowWindow", WORD), + ("cbReserved2", WORD), + ("lpReserved2", LPBYTE), + ("hStdInput", HANDLE), + ("hStdOutput", HANDLE), + ("hStdError", HANDLE) + ] +LPSTARTUPINFO = POINTER(STARTUPINFO) + +SW_HIDE = 0 + +STARTF_USESHOWWINDOW = 0x01 +STARTF_USESIZE = 0x02 +STARTF_USEPOSITION = 0x04 +STARTF_USECOUNTCHARS = 0x08 +STARTF_USEFILLATTRIBUTE = 0x10 +STARTF_RUNFULLSCREEN = 0x20 +STARTF_FORCEONFEEDBACK = 0x40 +STARTF_FORCEOFFFEEDBACK = 0x80 +STARTF_USESTDHANDLES = 0x100 + +# EnvironmentBlock + +class EnvironmentBlock: + """An object which can be passed as the lpEnv parameter of CreateProcess. + It is initialized with a dictionary.""" + + def __init__(self, dict): + if not dict: + self._as_parameter_ = None + else: + values = ["%s=%s" % (key, value) + for (key, value) in dict.iteritems()] + values.append("") + self._as_parameter_ = LPCWSTR("\0".join(values)) + +# Error Messages we need to watch for go here +# See: http://msdn.microsoft.com/en-us/library/ms681388%28v=vs.85%29.aspx +ERROR_ABANDONED_WAIT_0 = 735 + +# GetLastError() +GetLastErrorProto = WINFUNCTYPE(DWORD # Return Type + ) +GetLastErrorFlags = () +GetLastError = GetLastErrorProto(("GetLastError", windll.kernel32), GetLastErrorFlags) + +# CreateProcess() + +CreateProcessProto = WINFUNCTYPE(BOOL, # Return type + LPCWSTR, # lpApplicationName + LPWSTR, # lpCommandLine + LPVOID, # lpProcessAttributes + LPVOID, # lpThreadAttributes + BOOL, # bInheritHandles + DWORD, # dwCreationFlags + LPVOID, # lpEnvironment + LPCWSTR, # lpCurrentDirectory + LPSTARTUPINFO, # lpStartupInfo + LPPROCESS_INFORMATION # lpProcessInformation + ) + +CreateProcessFlags = ((1, "lpApplicationName", None), + (1, "lpCommandLine"), + (1, "lpProcessAttributes", None), + (1, "lpThreadAttributes", None), + (1, "bInheritHandles", True), + (1, "dwCreationFlags", 0), + (1, "lpEnvironment", None), + (1, "lpCurrentDirectory", None), + (1, "lpStartupInfo"), + (2, "lpProcessInformation")) + +def ErrCheckCreateProcess(result, func, args): + ErrCheckBool(result, func, args) + # return a tuple (hProcess, hThread, dwProcessID, dwThreadID) + pi = args[9] + return AutoHANDLE(pi.hProcess), AutoHANDLE(pi.hThread), pi.dwProcessID, pi.dwThreadID + +CreateProcess = CreateProcessProto(("CreateProcessW", windll.kernel32), + CreateProcessFlags) +CreateProcess.errcheck = ErrCheckCreateProcess + +# flags for CreateProcess +CREATE_BREAKAWAY_FROM_JOB = 0x01000000 +CREATE_DEFAULT_ERROR_MODE = 0x04000000 +CREATE_NEW_CONSOLE = 0x00000010 +CREATE_NEW_PROCESS_GROUP = 0x00000200 +CREATE_NO_WINDOW = 0x08000000 +CREATE_SUSPENDED = 0x00000004 +CREATE_UNICODE_ENVIRONMENT = 0x00000400 + +# Flags for IOCompletion ports (some of these would probably be defined if +# we used the win32 extensions for python, but we don't want to do that if we +# can help it. +INVALID_HANDLE_VALUE = HANDLE(-1) # From winbase.h + +# Self Defined Constants for IOPort <--> Job Object communication +COMPKEY_TERMINATE = c_ulong(0) +COMPKEY_JOBOBJECT = c_ulong(1) + +# flags for job limit information +# see http://msdn.microsoft.com/en-us/library/ms684147%28VS.85%29.aspx +JOB_OBJECT_LIMIT_BREAKAWAY_OK = 0x00000800 +JOB_OBJECT_LIMIT_SILENT_BREAKAWAY_OK = 0x00001000 + +# Flags for Job Object Completion Port Message IDs from winnt.h +# See also: http://msdn.microsoft.com/en-us/library/ms684141%28v=vs.85%29.aspx +JOB_OBJECT_MSG_END_OF_JOB_TIME = 1 +JOB_OBJECT_MSG_END_OF_PROCESS_TIME = 2 +JOB_OBJECT_MSG_ACTIVE_PROCESS_LIMIT = 3 +JOB_OBJECT_MSG_ACTIVE_PROCESS_ZERO = 4 +JOB_OBJECT_MSG_NEW_PROCESS = 6 +JOB_OBJECT_MSG_EXIT_PROCESS = 7 +JOB_OBJECT_MSG_ABNORMAL_EXIT_PROCESS = 8 +JOB_OBJECT_MSG_PROCESS_MEMORY_LIMIT = 9 +JOB_OBJECT_MSG_JOB_MEMORY_LIMIT = 10 + +# See winbase.h +DEBUG_ONLY_THIS_PROCESS = 0x00000002 +DEBUG_PROCESS = 0x00000001 +DETACHED_PROCESS = 0x00000008 + +# GetQueuedCompletionPortStatus - http://msdn.microsoft.com/en-us/library/aa364986%28v=vs.85%29.aspx +GetQueuedCompletionStatusProto = WINFUNCTYPE(BOOL, # Return Type + HANDLE, # Completion Port + LPDWORD, # Msg ID + LPULONG, # Completion Key + LPULONG, # PID Returned from the call (may be null) + DWORD) # milliseconds to wait +GetQueuedCompletionStatusFlags = ((1, "CompletionPort", INVALID_HANDLE_VALUE), + (1, "lpNumberOfBytes", None), + (1, "lpCompletionKey", None), + (1, "lpPID", None), + (1, "dwMilliseconds", 0)) +GetQueuedCompletionStatus = GetQueuedCompletionStatusProto(("GetQueuedCompletionStatus", + windll.kernel32), + GetQueuedCompletionStatusFlags) + +# CreateIOCompletionPort +# Note that the completion key is just a number, not a pointer. +CreateIoCompletionPortProto = WINFUNCTYPE(HANDLE, # Return Type + HANDLE, # File Handle + HANDLE, # Existing Completion Port + c_ulong, # Completion Key + DWORD # Number of Threads + ) +CreateIoCompletionPortFlags = ((1, "FileHandle", INVALID_HANDLE_VALUE), + (1, "ExistingCompletionPort", 0), + (1, "CompletionKey", c_ulong(0)), + (1, "NumberOfConcurrentThreads", 0)) +CreateIoCompletionPort = CreateIoCompletionPortProto(("CreateIoCompletionPort", + windll.kernel32), + CreateIoCompletionPortFlags) +CreateIoCompletionPort.errcheck = ErrCheckHandle + +# SetInformationJobObject +SetInformationJobObjectProto = WINFUNCTYPE(BOOL, # Return Type + HANDLE, # Job Handle + DWORD, # Type of Class next param is + LPVOID, # Job Object Class + DWORD # Job Object Class Length + ) +SetInformationJobObjectProtoFlags = ((1, "hJob", None), + (1, "JobObjectInfoClass", None), + (1, "lpJobObjectInfo", None), + (1, "cbJobObjectInfoLength", 0)) +SetInformationJobObject = SetInformationJobObjectProto(("SetInformationJobObject", + windll.kernel32), + SetInformationJobObjectProtoFlags) +SetInformationJobObject.errcheck = ErrCheckBool + +# CreateJobObject() +CreateJobObjectProto = WINFUNCTYPE(HANDLE, # Return type + LPVOID, # lpJobAttributes + LPCWSTR # lpName + ) + +CreateJobObjectFlags = ((1, "lpJobAttributes", None), + (1, "lpName", None)) + +CreateJobObject = CreateJobObjectProto(("CreateJobObjectW", windll.kernel32), + CreateJobObjectFlags) +CreateJobObject.errcheck = ErrCheckHandle + +# AssignProcessToJobObject() + +AssignProcessToJobObjectProto = WINFUNCTYPE(BOOL, # Return type + HANDLE, # hJob + HANDLE # hProcess + ) +AssignProcessToJobObjectFlags = ((1, "hJob"), + (1, "hProcess")) +AssignProcessToJobObject = AssignProcessToJobObjectProto( + ("AssignProcessToJobObject", windll.kernel32), + AssignProcessToJobObjectFlags) +AssignProcessToJobObject.errcheck = ErrCheckBool + +# GetCurrentProcess() +# because os.getPid() is way too easy +GetCurrentProcessProto = WINFUNCTYPE(HANDLE # Return type + ) +GetCurrentProcessFlags = () +GetCurrentProcess = GetCurrentProcessProto( + ("GetCurrentProcess", windll.kernel32), + GetCurrentProcessFlags) +GetCurrentProcess.errcheck = ErrCheckHandle + +# IsProcessInJob() +try: + IsProcessInJobProto = WINFUNCTYPE(BOOL, # Return type + HANDLE, # Process Handle + HANDLE, # Job Handle + LPBOOL # Result + ) + IsProcessInJobFlags = ((1, "ProcessHandle"), + (1, "JobHandle", HANDLE(0)), + (2, "Result")) + IsProcessInJob = IsProcessInJobProto( + ("IsProcessInJob", windll.kernel32), + IsProcessInJobFlags) + IsProcessInJob.errcheck = ErrCheckBool +except AttributeError: + # windows 2k doesn't have this API + def IsProcessInJob(process): + return False + + +# ResumeThread() + +def ErrCheckResumeThread(result, func, args): + if result == -1: + raise WinError() + + return args + +ResumeThreadProto = WINFUNCTYPE(DWORD, # Return type + HANDLE # hThread + ) +ResumeThreadFlags = ((1, "hThread"),) +ResumeThread = ResumeThreadProto(("ResumeThread", windll.kernel32), + ResumeThreadFlags) +ResumeThread.errcheck = ErrCheckResumeThread + +# TerminateProcess() + +TerminateProcessProto = WINFUNCTYPE(BOOL, # Return type + HANDLE, # hProcess + UINT # uExitCode + ) +TerminateProcessFlags = ((1, "hProcess"), + (1, "uExitCode", 127)) +TerminateProcess = TerminateProcessProto( + ("TerminateProcess", windll.kernel32), + TerminateProcessFlags) +TerminateProcess.errcheck = ErrCheckBool + +# TerminateJobObject() + +TerminateJobObjectProto = WINFUNCTYPE(BOOL, # Return type + HANDLE, # hJob + UINT # uExitCode + ) +TerminateJobObjectFlags = ((1, "hJob"), + (1, "uExitCode", 127)) +TerminateJobObject = TerminateJobObjectProto( + ("TerminateJobObject", windll.kernel32), + TerminateJobObjectFlags) +TerminateJobObject.errcheck = ErrCheckBool + +# WaitForSingleObject() + +WaitForSingleObjectProto = WINFUNCTYPE(DWORD, # Return type + HANDLE, # hHandle + DWORD, # dwMilliseconds + ) +WaitForSingleObjectFlags = ((1, "hHandle"), + (1, "dwMilliseconds", -1)) +WaitForSingleObject = WaitForSingleObjectProto( + ("WaitForSingleObject", windll.kernel32), + WaitForSingleObjectFlags) + +# http://msdn.microsoft.com/en-us/library/ms681381%28v=vs.85%29.aspx +INFINITE = -1 +WAIT_TIMEOUT = 0x0102 +WAIT_OBJECT_0 = 0x0 +WAIT_ABANDONED = 0x0080 + +# http://msdn.microsoft.com/en-us/library/ms683189%28VS.85%29.aspx +STILL_ACTIVE = 259 + +# Used when we terminate a process. +ERROR_CONTROL_C_EXIT = 0x23c + +# GetExitCodeProcess() + +GetExitCodeProcessProto = WINFUNCTYPE(BOOL, # Return type + HANDLE, # hProcess + LPDWORD, # lpExitCode + ) +GetExitCodeProcessFlags = ((1, "hProcess"), + (2, "lpExitCode")) +GetExitCodeProcess = GetExitCodeProcessProto( + ("GetExitCodeProcess", windll.kernel32), + GetExitCodeProcessFlags) +GetExitCodeProcess.errcheck = ErrCheckBool + +def CanCreateJobObject(): + currentProc = GetCurrentProcess() + if IsProcessInJob(currentProc): + jobinfo = QueryInformationJobObject(HANDLE(0), 'JobObjectExtendedLimitInformation') + limitflags = jobinfo['BasicLimitInformation']['LimitFlags'] + return bool(limitflags & JOB_OBJECT_LIMIT_BREAKAWAY_OK) or bool(limitflags & JOB_OBJECT_LIMIT_SILENT_BREAKAWAY_OK) + else: + return True + +### testing functions + +def parent(): + print 'Starting parent' + currentProc = GetCurrentProcess() + if IsProcessInJob(currentProc): + print >> sys.stderr, "You should not be in a job object to test" + sys.exit(1) + assert CanCreateJobObject() + print 'File: %s' % __file__ + command = [sys.executable, __file__, '-child'] + print 'Running command: %s' % command + process = Popen(command) + process.kill() + code = process.returncode + print 'Child code: %s' % code + assert code == 127 + +def child(): + print 'Starting child' + currentProc = GetCurrentProcess() + injob = IsProcessInJob(currentProc) + print "Is in a job?: %s" % injob + can_create = CanCreateJobObject() + print 'Can create job?: %s' % can_create + process = Popen('c:\\windows\\notepad.exe') + assert process._job + jobinfo = QueryInformationJobObject(process._job, 'JobObjectExtendedLimitInformation') + print 'Job info: %s' % jobinfo + limitflags = jobinfo['BasicLimitInformation']['LimitFlags'] + print 'LimitFlags: %s' % limitflags + process.kill() |